DC Control / DC Load
Delcon Solid State Relays - Ex Relays Series DC Control / DC Load
Relays for hazardous locations with DC input (control) voltage and DC load voltage.
EXI-relays for mA-size loads and EXO-relays for Ampere-size loads.
Main benefits comparing to electromechanical relays and opto coupled relays:
• No limited lifetime even with difficult loads, 10 years warranty
• High tolerance against noises
• Guaranteed switching on- and off-levels
• 100 % clear status indication
• Relatively high transient protection
• Extreme reliability
• No need for over dimension of the relay, all values are effective values
• Special relay types for inductive and high DC-loads, no need for extra protection elements
• No minimum load requirement
Approval ratings:
ATEX: II 3 G Ex nA IIC Gc
IECEx: Ex nA IIC Gc
HazLoc:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC
T4 (Ta ≤ 70 °C)
Product picture | Product name | Application | Control voltage | Load voltage | Max. current | Product document |
| EXO 5CH | Resistive loads | 5 VDC | 0...60 VDC | 3 A | PDF |
| EXO 5CHA | Inductive loads | 5 VDC | 0...250 VDC | 1,8 A | PDF |
| EXO 5CHX | Resistive loads | 5 VDC | 0...28 VDC | 10 A | PDF |
| EXO 5CHXSN | Resistive loads, DIN-rail | 5 VDC | 0...28 VDC | 10 A | PDF |
| EXI 12CH | Limit switches | 12 VDC | 0...28 VDC | 50 mA | PDF |
| EXO 12CH | Resistive loads | 12 VDC | 0...60 VDC | 3 A | PDF |
| EXO 12CHA | Inductive loads | 12 VDC | 0...250 VDC | 1,8 A | PDF |
| EXO 12CHX | Resistive loads | 12 VDC | 0...28 VDC | 10 A | PDF |
| EXO 12CHXSN | Resistive loads, DIN-rail | 12 VDC | 0...28 VDC | 10 A | PDF |
| EXI 24CH | Limit switches | 24 VDC | 0...28 VDC | 50 mA | PDF |
| EXI 24CHF | Fast connection | 24 VDC | 0...28 VDC | 50 mA | PDF |
| EXI 24CHL | Increased input current | 24 VDC | 0...28 VDC | 50 mA | PDF |
| EXO 24CH | Resistive loads | 24 VDC | 0...60 VDC | 3 A | PDF |
| EXO 24CHA | Inductive loads | 24 VDC | 0...250 VDC | 1,8 A | PDF |
| EXO 24CHA4 | Inductive loads | 24 VDC | 0...250 VDC | 4 A | PDF |
| EXO 24CHX | Resistive loads | 24 VDC | 0...28 VDC | 10 A | PDF |
| EXO 24CHXSN | Resistive loads, DIN-rail | 24 VDC | 0...28 VDC | 10 A | PDF |
| EXI 48CH | Limit switches | 48 VDC | 0...28 VDC | 50 mA | PDF |
| EXO 48CHA | Inductive loads | 48 VDC | 0...250 VDC | 1,8 A | PDF |
| EXO 48CHA4 | Inductive loads | 48 VDC | 0...250 VDC | 4 A | PDF |
| EXO 48CHX | Resistive loads | 48 VDC | 0...28 VDC | 10 A | PDF |
| EXO 48CHXSN | Resistive loads, DIN-rail | 48 VDC | 0...28 VDC | 10 A | PDF |
| EXI 125CH | Limit switches | 120 VDC | 0...28 VDC | 50 mA | PDF |
| EXO 120CHA | Inductive loads | 120 VDC | 0...250 VDC | 1,8 A | PDF |
| EXO 120CHA4 | Inductive loads | 120 VDC | 0...250 VDC | 4 A | PDF |
| EXO 220CHA | Inductive loads | 220 VDC | 0...250 VDC | 1,8 A | PDF |
| EXO 220CHA4 | Inductive loads | 220 VDC | 0...250 VDC | 4 A | PDF |
| EXI 250CH | Limit switches | 250 VDC | 0...28 VDC | 50 mA | PDF |