FL-GM Explosion-Proof Model

FL-GM Explosion-proof Model
Basic model of flame proof type.
Stem length adjustable model and protective tube extendable model and heat resistant model are available.
Various flange regulations are available. Consult us.

Operating Principles

When the deposits of measured substances restrain the paddle being rotated by the motor, the contact is output to stop the motor. When there is no more deposit left, the motor resumes rotation.

Model

NL-8B Standard Flange Type

Power Source

100~110VAC or 200~220VAC 50/60Hz

Power Consumption

4W

Contact Capacity

250VAC 5A Resistance Load

Rate of Rotation

1rpm (50Hz)

Allowable Temperature

below 50℃(in a tank)

Withstand Voltage

1500VAC
one minute for in between terminal and housing
(Each Terminal ~ Case)

Allowable Pressure

19.6kPa

Color

Gold

Process Connection

G1B or Equivalent to JIS 5K 65A

Enclosure Rating

Equivalent to IP55