Click to reach us online

KSL-DS4 Controller

KSL-DS4 Controller
Max. 4 detectors are connectable.
Indication is selectable from empty or remain.
Indication in the unit of m, %, t, m³.
Diagnostic function for buried weight and tape/wire cut.

Model

KSL-T8

KSL-T2

Power Voltage

100VAC or 200VAC, Single-phase 50/60Hz

100VAC or 200VAC, Single-phase 50/60Hz

Consumption

Max.150VA

Max.150VA

Allowable Temperature

ambient : -10℃~+50℃
(No freezing/condensation)
Inside tank : -10℃~+80℃
(No freezing/condensation)

ambient : -10℃~+50℃
(No freezing/condensation)
Inside tank : -10℃~+80℃
(No freezing/condensation)

Measuring Span

Standard 20m
(40m Option)

Standard 20m
(40m Option)

Measuring Method

Pulse Counting

Pulse Counting

Measuring Unit

1 pulse/10cm,
or 1 pulse/1cm

1 pulse/10cm

Measuring Accuracy

±1cm / ±10cm

±10cm

Motor

Single-phase, Reversible,
Output 40W
30 minutes rating, with brake

Single-phase, Reversible,
Output 40W
30 minutes rating, with brake

Body material

AC

SPC

Mounting Method

JIS 5K125A

JIS10K100A

Enclosure Rating

IP67

Equivalent to IP33

Output Signal

Current signal
DC4~20mA(indicate remains)
DC20~4mA(indicate vacated portion)
(User can set up either one)
Pulse contact signal
1 pulse / 1cm
(No-volt signal)
1pulse / 10cm
(User can set up either one)

Possible to control 4-20mA output by combining an optional control unit and P / I converter.

Output Contact

Reset Contact/
for Remote Indication Counter,
ON at the time of reset
Failure Alarm Contact/
Flickers when the measuring
tape is cut off.
The contact is closed when
the weight is buried.

Possible to control both upper and lower output by combining an optional control unit and P / I converter.