Moflon MT007 - Through Bore Slip Ring
Through bore 6.8mm, Overall Diameter: 24.8mm
MT007 series are standard, off-the-shelf products, Color-coded lead wires are used on both the stator and rotor for simplified electrical connections.It can provides a 12.7mm(1/2") through-bore for routing of hydraulic or pneumatic lines or hydraulic or pneumatic rotating shaft installation, and a compact 56mm outside diameter, features long life, fiber brush contact technology for ultimate performance in many challenging applications.

 

MT007
 
Specifications
Rings 2~12(see table as below) Current Signal/2A/5A
Voltage 250 VDC/VAC Max speed 250RPM
Through bore size 6.8mm Overall diameter 24.8mm
Housing Material Aluminium Alloy Torque 0.05N.m
Working life depends on working speed Contact material Precious Metal:Gold-Gold
Electrical noise <10 milliohms Contact Resistance <2mOhm
Dielectric strength 250VDC@50Hz Lead Wire UL Teflon® Awg22
Insulation resistance 1000MΩ@600VDC Lead Lengths 300mm(12")
Operating Temp. -40°C to 80°C Protection IP51
Mechanical vibratio MIL-SID-810E Humidity 10% to 70% RH
Materials Lead Free,RoHS compliant CE Certified YES
MT007-S12 12 Signal or 2A /ring
MT007-P0605 6 5A/ring
MT007-P0210 2 10A/ring

Standard drawings:

MT007-UF Optional No Flange mounting:

12 wires for one group color. from 13 ... 24, repeat the same color as 1 ... 12,indicated with number code pipe.

Lead wire Color codes
Rings# Color Code Rings# Color Code Rings# Color Code
1 BLK 5 YEL 9 GRY
2 BRN 6 GRN 10 WHT
3 RED 7 BLU 11 PINK
4 ORN 8 PURPLE 12 AZURY
 

 

  • Optional flange mounting.
  • Specified connectors and Heat-shrink tube.
  • Longer lead lengths available.
  • High temperature is optional.
  • Military Grade.


1.Main shaft mouted units:

A.Position the slip ring in the desired location and tighten both set screws to the shaft.Maximum torque 25Ib-in(DO NOT OVER TORQUE)
B.Route the wiring and make the neccessary connections.Do not allow the wiring to restrict free rotation of the slip ring.Do not constrain wiring such that wire flexing occurs.Doing so will ultimately cause failure(breakage of the wiring).

2.Housing mouted units:

A.Anti-Rotation tap used for connecting the stator of slip ring with the stationary member of euipment
B.Route the wiring and make the neccessary connections.Do not allow the wiring to restrict free rotation of the slip ring. 


Flange Mounting Instructions 

1. Align the mounting holes in the flange to mounting base and install flat washers and thread forming screws (NOT SUPPLIED) for plastic. Securely tighten screws.

2. Route the wiring and make the necessary connections. Do not allow the wiring to restrict free rotation of the slip ring.

3. Position a screw or dowel (NOT SUPPLIED) in the anti-rotation tab to the dimension as shown.

CAUTION: Because of possible geometric mismatching between the customer��s application and the slip ring, 'hard mounting' of both ends of the slip ring (i.e., securing the rotor and stator such that there is NO floating during operation) is not recommended and may cause premature failure



Build On Your Request/Special requirements

when we cann't find any one of standard part# to fit our application, what should we do?

Great! Moflon supply build-on-request service base on MT007 series, the delivery time of build-on-request is 2 weeks,and price is only 10%~30% more than the standard version.

Build-On-Request Flowing: