Click to reach us online

MUSB2121

Moflon MUSB2121 - USB Slip Ring
1 channel USB2.0 + 1~20 circuits Power/signal
MUSB2121,support 1 channel USB2.0 slip rings, with through bore size 12.7mm(0.5"), overall diameter 56mm, are standard, off-the-shelf, Color-coded lead wires are used on both the stator and rotor for simplified electrical connections.

 


MUSB2121-P0610-S06

MUSB2121
PART ODL SIGNAL/2A 10A 20A USB
MUSB2121-S02 56mm*37mm 2 0 0 1
MUSB2121-P0210 56mm*37mm 0 2 0 1
MUSB2121-S08 56mm*54mm 8 0 0 1
MUSB2121-P0810 56mm*54mm 0 8 0 1
MUSB2121-P0210-S06 56mm*54mm 6 2 0 1
MUSB2121-P0410-S04 56mm*54mm 4 4 0 1
MUSB2121-S14 56mm*70.5mm 14 0 0 1
MUSB2121-P1410 56mm*70.5mm 0 14 0 1
MUSB2121-P0410-S10 56mm*70.5mm 10 4 0 1
MUSB2121-P0810-S06 56mm*70.5mm 6 8 0 1
MUSB2121-S20 56mm*87.5mm 20 0 0 1
USB Specifications
USB USB1.0,USB2.0 connectors rotor:male,stator:male
BER 10E-11 Insert loss 2db
Power/signal Specifications
Circuits 1~20(see table as above) Current Signal(2A) or 10A
Voltage 250 VDC/VAC Max speed 600RPM
Through bore size 12.7mm(1/2") Overall diameter 56mm(2.2")
Housing Material Aluminium Alloy Torque 0.8N.m
Working life depends on working speed Contact material Precious Metal:Gold-Gold
Electrical noise <10 milliohms Contact Resistance <100mOhm(AWG16#,300mm)
Dielectric strength 1000VDC@50Hz Lead Wire UL Teflon®
Insulation resistance 1000MΩ@600VDC Lead Lengths 250mm
Operating Temp. -40°C to 80°C Protection IP51
Mechanical vibratio MIL-SID-810E Humidity 10% to 90% RH
Materials Lead Free,RoHS compliant CE Certified YES

*Please note: 10A rings parallel can be used as multiple 10A large current. 
For Example: 3 rings parallel = 1 wires 30A, please see order instructions
1)The operational life of the unit is dependent upon rotational speed, environment and temperature.
2)Lead Wire size: 2A/signal -> AWG22, 10A -> AWG16, 20A -> Awg14, colored code.
3)Electrical noise is dependent upon the rotating speed and current,voltage.

Standard drawings:

12 wires for one group color. from 13 ... 24, repeat the same color as 1 ... 12,indicated with number code pipe.

Lead wire Color codes
Rings# Color Code Rings# Color Code Rings# Color Code
1 BLK 5 YEL 9 GRY
2 BRN 6 GRN 10 WHT
3 RED 7 BLU 11 PINK
4 ORN 8 PURPLE 12 AZURY

Optional Flanges mounting:

At sometimes, we need a different flange for mounting instead, how should we do? 
Great! Moflon supply flange style as below:
(when you order, pls add FL01 at the suffix of Part#, for example: MUSB2121-06S-FL01 means MUSB2121-06S with optional flange FL01.)

 


  • If you don't see what you want in this website,let us know; we may already have it designed or we will modify a design to meet your requirements. In many cases the specifications in the catalog can be changed to include bore size, circuits number, higher current/voltage,flange, lead wire length,shielding,connectors,higher speed,IP68,military grade,higher temperature, mixed with pneumatic/hydraulic capability. Please ask if you don't see exactly what you need as only a small fraction of our Moflon slip rings are included in this catalog!
     

  • Can combine more wires:1-96Ring
  • Specified connectors and Heat-shrink tube.
  • Longer lead lengths available.
  • Shielded cables
  • Connectors
  • Frequencies up to 500 MHz
  • High-speed data transmission for fast Ethernet and EtherCat
  • Signal, Coax, and Power combinations
  • Thermocouples
  • Shock, Vibration, and Temperature Qualified
  • Pneumatic/Hydraulic Capability
  • High temperature---up to 450 degree
  • High Voltage & large Current(1000A)
  • Military Grade.

1.Main shaft mouted units:

A.Position the slip ring in the desired location and tighten both set screws to the shaft.Maximum torque 25Ib-in(DO NOT OVER TORQUE)
B.Route the wiring and make the neccessary connections.Do not allow the wiring to restrict free rotation of the slip ring.Do not constrain wiring such that wire flexing occurs.Doing so will ultimately cause failure(breakage of the wiring).

2.Housing mouted units:

A.Anti-Rotation tap used for connecting the stator of slip ring with the stationary member of euipment
B.Route the wiring and make the neccessary connections.Do not allow the wiring to restrict free rotation of the slip ring. 


Flange Mounting Instructions 

1. Align the mounting holes in the flange to mounting base and install flat washers and thread forming screws (NOT SUPPLIED) for plastic. Securely tighten screws.

2. Route the wiring and make the necessary connections. Do not allow the wiring to restrict free rotation of the slip ring.

3. Position a screw or dowel (NOT SUPPLIED) in the anti-rotation tab to the dimension as shown.

CAUTION: Because of possible geometric mismatching between the customer��s application and the slip ring, 'hard mounting' of both ends of the slip ring (i.e., securing the rotor and stator such that there is NO floating during operation) is not recommended and may cause premature failure



 

Build On Your Request/Special requirements

MOFLON specialize in customized solutions, Now our models have over 12000, and over 80% model are customized on customer request and base on technology and full experience, our slip ring solution including traditionary carbon brush, gold wire contact, gold fiber brush contact, no contact transmit, each solution application depend on the customer real application request with economically, high quality and reliability.


Now, Let's start - how to build on request?

Please see ordering information instructions as below:

 

MUSB2121

 


Build-On-Request Flowing: