Operation Temp 0℃~ 230℃
Differential Standards:10K~30K
Temp Tolerance Standards:±3~10℃ ※Depend on Operation Temp
Max Ambient Temp 230℃
Resistance between Terminals
Less than 30mΩ (Initial value)
Insulation Resistance Not less than 1,000MΩ/DC500V
Dielectric strength Not less than AC1,500V/1min.
Not less than AC1,800V/1sec
Endurance More than 10,000cycles (Standards)
NGT - Type 07&09 Ceramic CaseNGT - Type 07&09 Ceramic Case

 

 

 

 

 

  • Compliance with RoHS Directives.
  • This is not splash or water proof type.