ZCode-RC
|
Applications
|
guard doors, sliding guards or protective covers
|
Correspondents to the standards
|
ISO 13849-1; EN ISO 14119; EN 60204-1; EN 60947-5-3; UL508; CSA-C22.2 No. 14
|
Approvals
|
CE, TÜV, UL
|
Power Supply
|
DC 24 V; +/- 10 %
|
Number of Outputs
|
2 contactless safety outputs, 1 auxiliary outputs
|
Contact rating (safe- & auxiliary outputs)
|
DC 24 V; max. 500 mA; short-circuit proof
|
Minimum load current
|
DC 10 V; 1 mA
|
Switching distance recommented, maximum
|
5 mm, 10 mm close / 22 mm open
|
Base material
|
Red PES (Polyester)
|
Ambient temperature
|
-25 °C to +80 °C
|
PL; Kat.; SILCL (EN ISO 13849-1; EN /IEC 62061)
|
PL e; Kat.4; SILCL3
|
Vibration-, shock resistance
|
10-55 Hz / 1 mm, 11 ms / 30 g
|
Weight, dimensions (D x L)
|
110 g, 30 x 60 mm (switch: 15 mm)
|
Order No. with M12 connector, inclusive actuator
|
940181
|