Click to reach us online

TALOS TB-I14O3h

Features

  • 3 safe independent switching PNP-semiconductor
  • outs Stop category 0 or 1.
  • 14 secure access
  • 3 start inputs (auto start or manual start monitored)
  • 6 safe independent switching PNP-semiconductor outputs
  • 16 pre-defined standard configurations
  • Detailed and clear monitoring
  • Easy and intuitive operation. Direct control
  • Push / swivel with front
  • Approved and approved for the highest safety standards: PL e / Cat. 4 according to EN ISO 13849-1, continuous furnaces and auxiliary equipment operating according to EN 50156-1

TALOS® TB-I14O3 - up to 99 h

Safety function

Emergency stop monitoring, safety guard monitoring, light grids monitoring, furnaces in continuous operation, stop category 0/1

Certified according to

EN ISO 13849-1:2015, EN 50156-1:2015, EN62061:2005 + AC: 2010 + A1:2013 + A2:2015, IEC 61508 Parts 1-7:2010, IEC 61511-1:2016, EN 746-2:2010

Approvals

CE, TUV

Supply voltage

UB: DC 24 V (+/- 15 %)

Power consumption

3,8 W (all inputs activated / no load operation)

Number of inputs

14 safe inputs / 3 start inputs

Number of safe semiconductor outputs

3

Switching capability per safe output

UB / 500 mA; PNP; short circuit proof

Adjustable delay

0 - 99 h

Number of auxiliary semiconductor outputs

6

Switching capability per auxiliary output

1 x UB / 500 mA; 5 x UB / 50 mA; PNP; short circuit proof

Number of pulsed outputs

4

Input voltage

DC 24 V (+/- 15 %)

PL; Cat.; SILCL (EN ISO 13849-1; EN 62061)

PL e; Kat. 4; SILCL 3

Dimensions

45 x 99 x 118 mm

TALOS ® TB-I14O3h incl. plug-in screw terminals

474602

TALOS ® TB-I14O3h incl. plug-in spring-cage terminals

475602