Hollow Shaft Encoder - HRS Series
HRS - Cube Style Hollow Shaft fits 1" (25mm) shaft
The model HRS is an optical hollow shaft encoder with up to a 1" / 25mm blind shaft bore in a standard 2-1/4" cube style housing that mounts directly on an existing shaft assembly. A flexible mounting bracket or other type of tether allows the encoder to float on the shaft without rotating. The HRS generates up to 3 square wave outputs.
Standard Features and Options:
• CE Marked
• Surge protection available
• Short circuit and ESD protection are available on most models with the anit-jitter option, and many others (please inquire)
MECHANICAL
- Weight: 11 oz. (312 grams)
- Maximum speed: 3,000 rpm
- Shaft Loading:
- Radial: 25 lb. (11.3 kg.) max.
- Axial: 15 lb. (6.8 kg.) max.
- Bearing Life (L10): 36 x 106/RPM = hours
- Materials:
- Case and Shaft: Aluminum
- Switch Access Door: Plastic
- Connector: 6-pin, MS3102A-14S-6P
ELECTRICAL
- Power Input (specify voltage when ordering):
Supply Voltage
|
R Values (see fig 1)
|
5 ± 5% vdc
|
1K ohms
|
12 or 15 ± 5% vdc
|
2.2K ohms
|
24 ± 5% vdc
|
3.3K ohms
|
8 to 30 vdc
|
3.3K ohms
|
- Supply Current: 50ma maximum (no load)
- Output Current (I0): 50ma max source/sink
- Output Circuits: (specify when ordering)
- Push/Pull (Combined sourcing/sinking)
- Current sinking NPN transistor
- NPN open collector
(Vcc=30 vdc maximum)
- Current sourcing PNP transistor
- RS422 differential line driver (MC3487 device; must be ordered with 5, 5R or 8-30 supply voltage)
- Output Protection:
- Short Circuit (all Programmable and AJ models; inquire for others)
- ESD to 8KV direct and 25KV air
- Pulse On·Off Ratio: 50% ± 10%
- Pulse Interval Jitter: ±10%
- Quadrature Deviation: 30° (max)
- Pulse rise time: 2 µsec (max)
- Pulse fall time: 5 µsec (max)
- Voltage (high): Vin-2.5 vdc (min)
- Voltage (low): 1.5 vdc (max)
- Index Pulse: approximately the width of 1 pulse on output A
(600 rpm, VIN=24vdc, 10ma < I0 < 50ma, 25° C)
- Output Waveform: 50/50 squearewave
- Operating temperature: 0° to 70° C
- Pulse Rate: 0 - 30 kHz
- Pulses per Revolution: (specify when ordering) 1 to 1200.
|
PROGRAMS (for programmable versions)
The HRS-P is preconfigured with one of the following programs. Others are available.
- 64AJ - Single pulse output on A with selectable ppr from 1 through 64, and the anti-jitter feature.
ELECTRICAL CONNECTIONS
- NPN or PNP transistor outputs:
6-Pin Connector
|
Function
|
Wire Color
|
A
|
Common
|
Black
|
B
|
+vdc
|
Red
|
C
|
Output Z or C
|
Brown*
|
D
|
Output A
|
White
|
E
|
Output B
|
Green
|
*Output Z is green if Output B is not used.
6-Pin Connector
|
Function
|
Wire Color
|
A
|
Common
|
Black
|
B
|
+vdc
|
Red
|
C
|
Output A
|
White
|
D
|
Output Ā
|
Blue1
|
E
|
Output B2
|
Green
|
F
|
Output B̄2
|
Brown
|
- Output Ā is green if Output B is not used.
- These are Outputs Z / Z̄if B / B̄ are not used.
ACCESSORIES
- Cable Assembly (C6·x·10): 10ft. (3m), x conductor shielded cable & connector Other lengths are available.
CE mark requires Photocraft cable, and surge protection if cable exceeds 100' (30m) or leaves the building.
- Flexible Mounting Bracket (MB·FB1): flexible stainless steel that allows for axial and angular shaft misalignment.
MOUNTING INSTRUCTIONS
- Slide HRS onto shaft, fasten flexible mounting bracket or tether to frame, and then tighten shaft set screws.
- Attach the cable leads to the control device (e.g. PLC) ensuring that the power supply meets specifications.
- If programmable then set the switches. Switches can be changed at any time.
- Attach the cable to the encoder.
|