Click to reach us online

W92

Bar-stock thermowells, stepped shank, with flanged connection, NP 6…100
Thermowells are used to to protect the measuring instrument from corrosion, high pressure or hgih fluid velocity and to allow the measuring instrument removal for recalibration or replacement without affecting the process system. The W92 serie includes bar-stock thermowells with flanged process connection and they are suitable for heavy work conditions. These thermowells have a stepped-shank immersion length for a better process temperature measuring sesibility.

W92
Industrial sector:
  • Chemical, Petrochemical
  • Energy
  • Oil & Gas
Specific applications:
  • ASME PTC 19.3 TW version
  • Crystallizzing fluids
  • Viscous fluids
  • Corrosive fluids
Conformity:
  • ASME PTC 19.3 TW
Function:
  • Accessories
Material:
  • Stainless steel and special materials
Accessories:
  • Thermowell
Total length:
  • maximum 1000mm
Special materials:
  • Monel 400, Hastelloy C276, Alloy 625, Alloy 825, Duplex SAF 2205, Superduplex SAF 2507
Operating pressure:
  • 100bar @400°C
W92, a, the, or, to, measuring, with, process, The, thermowells, for, connection, and, are, stepped, instrument, flanged, recalibration, NP, replacement, without, affecting, 6…100, from, system, corrosion, W92, serie, includes, bar-stock, high, pressure, Thermowells, hgih, fluid, velocity, they, shank, suitable, used, heavy, work