ZLS
|
Applications
|
Protection of large hazardous zones, e.g.
conveyer belts, extrusion plants and cutting machinery
|
Certified according to
|
IEC 947-5-1, IEC 60947-5-5, IEC 60947-5-1, ISO 14119,
ISO 13850, ISO 13949-1
|
Approvals
|
CE, TUV
|
Certified according to
|
IEC 947-5-1, IEC 60947-5-5, IEC 60947-5-1, ISO 14119,
ISO 13850, ISO 13949-1
|
Approvals
|
CE, TUV
|
Safety contacts
|
3 NO / 1 NC
|
Contact rating, minimum load current
|
AC-15: 3 A / 240 V; DC-13: 2.5 A / 24 V
|
Typical operating force, rope pulled
|
< 125 N
|
Rope spans
|
80 m
|
Ambient temperature
|
-25 °C to +80 °C
|
LED
|
DC 24 V
Red flashing or steady - unsafe condition
Green steady - safe condition
|
Housing
|
Die-Cast, painted yellow
|
IP Rating
|
IP67
|
PL; Cat.; SILCL (EN ISO 13849-1; EN ISO 13850, EN 62061)
|
PL e; Cat.4; SILCL3
(in combination with ZANDER safety relays)
|
Mechanical reliability
|
1,5 x 10⁶ operations
|
Approx. weight
|
820 g
|
Order No.
|
940010
|