Hokuyo - VMH200
Hot Metal Position Detector - HMPD
Wide range output voltage!
This device consists of a camera and a controller and detects the infrared ray from the hot metal and outputs the analog signal.
Feature
CCD camera system is applied and 2 pcs of camera can be connected to 1 pce of controller
Analog output can be displayed with 7 segment LED on the controller. Current analog value can be read directly.
Waveform of camera can be displayed with maintenance mode by connecting PC. It is possible to check light-reception level or influence by disturbance light.
Specifications
·Sensor head (Camera)
Model No.
|
VMH-KZ20
|
Power source
|
Suuplied from controller
|
Detectable object
|
Hot metal with 750 degrees C or more
|
Min.detectable objects
|
Detection view × 1/2,048
|
Light-receiving element
|
CCD image sensor with 2,048 bits
|
Detection view
|
700mm × (distance)m
|
Resolution
|
Detection view × 1/2,048
|
Scanning cycle
|
3msec/6msec(changeover)
|
Ambient temperature
|
-5 to +55 degrees C, -5 to +80 degrees C when cooling
|
Ambient humidity
|
45 to 85%RH(not icing, not condensing)
|
Cooling water
|
Pressure: 100 to 200kPa, withstand pressure: 500kPa, amount: 4 to 6lit/min, temperature: 35 degrees C or less, quality: industrial clean water
|
Air for dust-proof(option)
|
Withstand pressure: 1MPa, amount: 100lit/min, quality: industrial clean air(available only when using air-purge)
|
Hood
|
Detachable on-air dust-purge hood
|
Protective structure
|
IP64(IEC standard)
|
Case materials
|
Aluminum casting
|
Weight
|
Approx. 3.5kg
|
* Wide area type VMH-KZ30 is available.
·Controller
Model No.
|
VMH-A200
|
Power source
|
100 to 240VAC(50/60Hz)(Voltage fluctuation range 85 to 264VAC)
|
Current consumption
|
40VA or less
|
Analog output
|
Max. -10 to +10VDC ±0.1% 10mA(output impedance 100Ω) 2pcs(each sensor head)
|
Output
|
Object-existing(DETECTION)
|
1C photo-mos relay, Voff≤AC/DC 250V, lo≤AC/DC 100mA 2pcs(each camera)
|
Light-receiving amount lowering(LOW)
|
Photo-coupler, Vce≤DC 80V, lc≤DC 50mA 1pce(OR output for each camera)
|
Signal-existing(SIGNAL)
|
1a photo-mos relay, Voff≤AC/DC 250V, lo≤DC 250V, lo≤AC/DC 100mA 1pce(OR output for each camera)
|
Device trouble(RUN)
|
Light-receiving amount lowering(LOW)
|
Input
|
Camera sensitivity changeover, photo-coupler 1 pce(common use for camera 1 & 2)
24VDC 50mA or less
|
Response time
|
6msec/12msec or less(changeover)
|
Connection
|
For communication: 9 pins D-sub connector
For sensor head: exclusive cable
|
Display
|
7-segment LED, 4 digits × 2(analog output per camera)
Red LED 5 points(object-existing 2 points(each camera), signal-existing, light-receiving amount lowering, device trouble, each 1 point(OR per camera)
PC screen(analog, waveform, setting state etc.) available only when connecting PC
|
Ambient temperature
|
-10 to +50 degrees C
|
Ambient humidity
|
45 to 85%RH(not icing,not condensing)
|
Insulation resistance
|
20MΩ or more(between power/output contact and case by 500V megger)
|
Withstand voltage
|
AC1,500V, 1min.(between power/output contact and case)
|
Vibration resistance
|
Double amplitude 1.5mm, 10 to 55Hz, each 2 hour in X, Y and Z directions
|
Impact resistance
|
500m/s2, each 10 times in X, Y and Z directions
|
Case materials
|
Steel plate(SECC)
|
Weight
|
Approx. 2kg
|
External dimension
Controller