Click to reach us online

MW5360

MW5360 - Moflon Large Current Slip Ring
3wires * 60A,bore size 50.8mm(2")
MW5360 slip rings, Designed for 3wires * 60A, with through bore size 50mm(1.97"), overall diameter 120mm, are standard, off-the-shelf, Color-coded lead wires are used on both the stator and rotor for simplified electrical connections.

MW5360
Specifications
Wires 3 Current 60A
Voltage 600 VDC/VAC Max speed 250RPM
Overall diameter 120mm Length 100mm
Contact Material Precious Metal:gold-gold Contact Resistance <100mOhm(AWG16#,250mm)
Housing Material AL Alloy Torque 0.5N.m
Working life depends on working speed Electrical noise <10mΩ
Dielectric strength 1000VDC@50Hz Lead Wire UL Teflon® 14Awg,3 parallel
Insulation resistance 1000MΩ@600VDC Lead Lengths 250mm
Dielectric strength 1000VDC@50Hz Lead Wire UL Teflon® 14Awg,3 parallel
Insulation resistance 1000MΩ@600VDC Lead Lengths 250mm
Operating Temp. -40°C to 80°C Protection IP51
Mechanical vibratio MIL-SID-810E Humidity 10% to 90% RH
Materials Lead Free,RoHS compliant CE Certified YES

Notes:
1)The operational life of the unit is dependent upon rotational speed, environment and temperature.
2)Lead Wire size: 2A/signal -> AWG22, 10A -> AWG16, 20A -> Awg14, colored code.
3)Electrical noise is dependent upon the rotating speed and current,voltage.

Standard drawings:

Lead wire Color codes
Rings# Color Code
1 RED
2 BLK
3 Yellow
 

 

  • If you don't see what you want in this website,let us know; we may already have it designed or we will modify a design to meet your requirements. In many cases the specifications in the catalog can be changed to include bore size, circuits number, higher current/voltage,flange, lead wire length,shielding,connectors,higher speed,IP68,military grade,higher temperature, mixed with pneumatic/hydraulic capability. Please ask if you don't see exactly what you need as only a small fraction of our Moflon slip rings are included in this catalog!
     
  • Optional flange mounting.
  • Specified connectors and Heat-shrink tube.
  • Longer lead lengths available.
  • High temperature is optional.
  • Military Grade.

Flange Mounting Instructions 

1. Align the mounting holes in the flange to mounting base and install flat washers and thread forming screws (NOT SUPPLIED) for plastic. Securely tighten screws.

2. Route the wiring and make the necessary connections. Do not allow the wiring to restrict free rotation of the slip ring.

3. Position a screw or dowel (NOT SUPPLIED) in the anti-rotation tab to the dimension as shown.

CAUTION: Because of possible geometric mismatching between the customer��s application and the slip ring, 'hard mounting' of both ends of the slip ring (i.e., securing the rotor and stator such that there is NO floating during operation) is not recommended and may cause premature failure





Shaft Mounting Instructions(For Through bore style) 

1.Main shaft mouted units:

A.Position the slip ring in the desired location and tighten both set screws to the shaft.Maximum torque 25Ib-in(DO NOT OVER TORQUE)
B.Route the wiring and make the neccessary connections.Do not allow the wiring to restrict free rotation of the slip ring.Do not constrain wiring such that wire flexing occurs.Doing so will ultimately cause failure(breakage of the wiring).

2.Housing mouted units:

A.Anti-Rotation tap used for connecting the stator of slip ring with the stationary member of euipment
B.Route the wiring and make the neccessary connections.Do not allow the wiring to restrict free rotation of the slip ring. 
 

Typical Application

  • Small wind turbine.
  • Automation.
  • Cut equipments.
  • Rotary table
  • Robotics
  • Laboratory equipmen