SR2C

Safety Relay SR2C

Features

  • 2 secure, redundant relay outputs
  • Connection:
  • Emergency stop buttons, Safety switches, Non-contact safety switches, OSSD Outputs
  • Single and dual channel operation possible
  • Feedback loop or expansion modules to monitor the downstream contactors
  • Cyclical monitoring of output contacts
  • Switching status indication via LED 2 start-up possible: Manual start monitored, Automatic start
  • PL e, SILCL 3, up to category 4
SR2C

SR2C

Safety function

Emergency stop monitoring,
safety guard monitoring,
light grids monitoring

Certified according to

EN 60204-1; DIN EN ISO 13849-1; EN 62061; IEC 61508 Teil 1-2 und 4-7; IEC 61511-1

Approvals

CE, TUV

Supply voltage

AC/DC 24 V / AC 115 V / AC 230 V

Number of safe relay contacts

2

Max. switching capability of safe relay contacts

6 A / 250 VAC resistive load

Number of auxiliary relay contacts

-

Number of non time-delayed contacts

2

Number of time-delayed contacts

-

Starting behavior

Automatic start or manual,
monitored start

PL; Cat.; SILCL (EN ISO 13849-1; EN 62061)

PL e; Cat. 4; SILCL 3

Width

22.5 mm

Order No. fixed screw terminals

472152 (24 V) / 472151 (115 V) / 472150 (230 V)

Order No. plug-in screw terminals (no UL)

474152 (24 V) / 474151 (115 V)/ 474150 (230 V)

Order No. plug-in dual tensile spring terminals (no UL)

475152 (24 V) / 475151 (115 V) / 475150 (230 V)

Order No. EKLS4; set of plug-in screw terminals

472592

Order No. EKLT4; set of plug-in dual tensile spring terminals

472595