Product name
|
Laser range finder
|
Type
|
UXM-30LXH-EWA
|
Light source
|
Semiconductor laser, λ=905nm, safety class of the laser = 1
|
Power supply voltage
|
10 to 30VDC
|
Power supply current
|
Steady-state current: 600mA or less at 12VDC, 300mA or less at 24VDC
Starting current: 1.5A or less at 12VDC, 0.75A or less at 24VDC
Heater in use(0°C or below): 1.25A or less at 12VDC, 1.25A or less at 24VDC
|
Electric power consumption
|
7.2W or less(at steady-state)
Heater in use(0°C or below: 15W or less at 12VDC, 30W or less at 24VDC)
|
Detecting distance and object to be detected
|
Guaranteed value of detection:
0.1 to 30m*1(Reflectance of 10%, black paper, 500mm×500mm)
0.1 to 80m*1(Reflectance of 90%, white Kent paper, 1,000mm×1,500mm)
Maximum detecting distance: 120m
Minimum object to be detected: 33mm(5m), 65mm(10m), 200mm(30m)
|
Average accuracy by distance
|
10% reflectance, black paper, 0.1 to 15m:±30mm, 15 to 30m:±50mm*1
0.1 to 30m:±50mm*2 Ambient illuminance: 3,000 lux or less
0.1 to 20m:±50mm*2 Ambient illuminance: 100,000 lux or less
|
90% reflectance, white Kent paper, 0.1 to 30m:±30mm*1
0.1 to 30m:±50mm*2 Ambient illuminance: 3,000 lux or less
0.1 to 20m:±50mm*2 Ambient illuminance: 100,000 lux or less
|
Measurement resolution
|
Unit of 1mm
|
Repeat accuracy
|
10% reflectance, black paper, 0.1 to 15m: σ<10mm, 15 to 30m: σ<15mm*1
0.1 to 30m: σ<20mm*2 Ambient illuminance: 3,000lux or less
0.1 to 20m: σ<30mm*2 Ambient illuminance: 100,000lux or less
|
90% reflectance, white Kent paper, 0.1 to 30m: σ<10mm*1
0.1 to 30m: σ<15mm*2 Ambient illuminance: 3,000lux or less
0.1 to 30m: σ<30mm*2 Ambient illuminance: 100,000lux or less
|
Scanning angle
|
190°
|
Angular resolution
|
Approx. 0.125°(360°/2880 divisions)
|
Scanning time
|
50ms(rotating speed of motor: 1200rpm)
|
Interface
|
Ethernet 100BASE-TX(Auto-negotiation)
|
Output
|
OUTPUT 3 points: Synchronization master output, synchronization output, failure output
|
Input
|
INPUT 1 points: Synchronization input
|
Starting time
|
Operation starts within 30sec after turning on of power supply.
|
Indication lamp
|
Indication lamp for power supply and operation(green), indication lamp for communication measurement(orange)
Regarding the operation of indication lamps, refer to sub-clause 7.2.
|
Ambient operating temperature, humidity
|
-10 to +50°C 85%RH(However, dew condensation and freezing should not exist.)
|
Resistance to weather
|
Detecting distance becomes shorter due to rain, snow, and sunlight.*3
|
Vibration resistance
|
10 to 55Hz, plural amplitude: 1.5mm in X, Y, Z directions, each 2 hours
55 to 200Hz 19.6m/s2 Sweep: 2 minutes in X, Y, Z directions, each 1 hour
|
Resistance to shock
|
196m/s2 in X, Y, Z directions, each 10 times
|
Protective structure
|
IP67
|
Insulation resistance
|
10MΩ
|
Mass
|
1200g
|
Material
|
Front face of the case, optical windows: Polycarbonate, Back face of the case: Aluminum
|
Outside dimension(W×D×H)
|
124mm × 126mm × 150mm(connector not included)
|