Electrical Data
|
|
Mechanical Data
|
|
Supply voltage
|
5 V: LD, SI
|
Shaft ∅
|
6 mm
|
|
5 V o. 8 ... 30 V: IX, TL, OC, QI
|
Outer ∅
|
36,5 mm
|
|
8 ... 15 V: KI
|
Weight
|
ca. 85 g
|
|
8 ... 35 V: KS
|
Accuracy
|
<± 360° / (Line counts x 20)
|
Current requirement (without load)
|
max. 100 mA:
|
Permissible speed
|
max. 3.500 min-1
|
|
LD, IX, KS, KI, TL, OC, QI, SI
|
Starting torque (25°C)
|
< 0,001 Nm
|
Output load
|
± 20 mA (RS422): LD, IX
|
Rotor intertia
|
0,15 x 10-6 kgm2
|
|
40 mA: OC
|
Vibration
|
100 m/s2
|
|
50 mA: KS, KI
|
Shock
|
300 m/s2
|
|
40 mA (3,3 kOhm): TL
|
Rotor intertia
|
-25 °C ... 85 °C (-13 °F ... 185 °F)
|
|
8 mA (120 Ohm): SI
|
|
-25 °C ... 75 °C (-13 °F ... -103 °F) for QI
|
|
11 µAss (1 kOhm): QI
|
Protection class
|
IP 64
|
Output frequency
|
0 ... 100 kHz: TL, OC
|
Line counts
|
1 ... 4.096
|
|
0 ... 160 kHz (-3 dB): QI, SI
|
Output signals
|
RS422, TTL, OC, KS, KI, 1Vss, 11 µAss
|
|
0 ... 400 kHz: IX
|
Cable output
|
axial or radial
|
Cable length
|
max. 5 m: QI
|
Cable
|
with tubular rivet or connector
|
|
max. 30 m: TL, OC
|
Optional
|
sealed bearing
|
|
max. 50 m: KS, KI
|
|
square flange receptacle
|
|
max. 100 m: LD, IX
|
|
|
|
max. 150 m: SI
|
|
|
Interpolation
|
5-fach: IE; 10-fach: IM
|
|
|
|
25-fach: IQ 50-fach: IP
|
|
|
Zero Index
|
1 Z "high" if A "high"
|
|
|
|
5 Z "high" if A+B "high"
|
|
|