Linear Encoder L23 Modular sealed photoelectric linear encoder L23 has measuring length up to 20 meters and more on special order.
Mechanical Data
Measuring lengths (ML), mm
250, 300, 350, 400, 450, 500...20000 (more on option)
Accuracy grades to any meter within the ML (at 20°C)
± 10; ± 5; ± 3 μm (optional)
Grating period
400 μm; 40 μm; 20 μm
Reference marks (RI)
- N: without reference mark - M: every 50 mm - P (optional): RI number and place
Max. traversing speed
- when T = 400 μm and resolution 100, 50, 10 μm: 120 m/min - when T = 40 μm and - resolution 10.5 μm: 80 m/min - resolution 1 μm: 25 m/min - when T = 20 μm and - resolution 5 μm: 60 m/min - resolution 0.5 μm: 12 m/min
Required moving force with sealing lips
< 4 N
Protection (IEC 529)
- without compressed air: IP54 - with compressed air (optional): IP64
Weight
0.4 kg + 2.8 kg/m
Operating temperature
0...+50°C
Storage temperature
-20...+70°C
Permissible vibration (10 to 2000 Hz)
≤ 100 m/s²
Permissible shock (11 ms)
≤ 150 m/s²
Coefficient of thermal expansion
10.6 x 10-6 °C
Electrical Data
Version
L23-F Π (TTL or HTL)
Supply voltage
+ 5 V ± 5 %; 65 mA + 12 V ± 5 %; 65 mA
Light source
LED
Resolution
100, 50, 10, 5, 1, 0.5 μm (after 4 - fold in subsequent electronics)
Incremental signals
Differential square-wave U1 / U1 and U2 / U2
Reference signal
Differential square-wave U0 / U0
Signal levels at load current 20 mA
- low (logic "0") < 0.5 V at Up = ±5V - high (logic "1") > 2.4 V at Up = ±5V - low (logic "0") < 1.5 V at Up = ±12V (HTL) - high (logic "1") > (Up - 2)V at Up = ±12V (HTL)
Direction of signals
U2 lags with U1 (displacement from left to right and head position down)
Standard cable length
4 m armored; without connector
Maximum cable length
25 m