Click to reach us online

L50

Linear Encoder L50
Modular photoelectric sealed linear encoder L50 has measuring length from 3240 mm up to 30040 mm.

Mechanical Data 

Measuring lengths (ML), mm

from 3240 up to 30040 (length of each module with steps 200 mm)

Accuracy grades to any meter within the ML (at 20°C)

± 10 μm/m

Grating period

40 μm

Reference marks (RI)

 

- C: at coded distance 80 mm
- P: at constant step 50 mm
- E: selectable through magnet

Max. traversing speed

1 m/min

Required moving force with sealing lips

< 6 N

Protection (IEC 529)

- without compressed air: IP53
- with compressed air (optional): IP64

Weight

1.8 kg + 3.3 kg/m

Operating temperature

0...+50°C

Storage temperature

-20...+70°C

Permissible vibration (40 to 2000 Hz)

≤ 100 m/s²

Permissible shock (11 ms)

≤ 300 m/s²

Coefficient of therman expansion

10.6 x 10-6 °C

Electrical Data 
 

Version

L50-AV ∫ 1 Vpp

L50-F Π TTL

Supply voltage

+ 5 V ± 5 % / 100 mA (120 Ω)

+ 5 V ± 5 % / 150 mA (120 Ω)

Light source

LED

LED

Resolution

up to 0.1 µm depending on external subdividing electronics

10; 5; 1; 0.5 μm (after 4 - fold dividing in subsequent electronics)

Incremental signals

Differential sine +A / -A and +B / -B
Amplitude at 120 kΩ load:
- A = 0.6 - 1.2 V
- B = 0.6 - 1.2 V

Differential square-wave U1 / U1 and U2 / U2. Signal levels at 20 mA load current:
- low (logic "0") ≤ 0.5 V 
- high (logic "1") ≥ 2.4 V

Reference signal

Quasi-triangular R magnitude at 120 Ω load:
- R = 0.25 - 0.8 V (usable component)

One differential square-wave U0 / U0 per revolution. Signal levels at 20 mA load current:
- low (logic "0") ≤ 0.5 V 
- high (logic "1") ≥ 2.4 V

Direction of signals

B lags A at reading head displacement from left to right

U2 lags U1 at reading head displacement from left to right

Standard cable length

4 m

4 m

Maximum cable length

150 m

50 m