Click to reach us online

A170

Rotary Encoder A170
Precision photoelectric angle encoder A170 is used for precise angular displacement measurement of rotary tables, dividers, comparators, antennas and other high precision equipment. It provides information about the value and direction of motion. The encoder is used in automatic control, on-line gauging, process monitoring systems, etc.

Mechanical Data 

Number of output pulses per revolution

18000-1800000 ppr

Line number on disc (z)

18000; 36000

Reference signal
 

- standard: 1 per shaft revolution
- distance coded for z = 18000: 36 per shaft revolution
- distance coded for z = 36000: 72 per shaft revolution

Permissible mech. speed

≤ 1000 rpm

Max. operating speed

300 to 500 rpm

Accuracy

± 2.5 arc. sec; ± 5.0 arc. sec

Permissible shaft load

- axial: ≤ 30 N
- radial: ≤ 30 N

Starting torque at 20°C

≤ 0.012 Nm

Rotor moment of inertia

< 3.7x10-4 kgm2

Protection (IEC 529)

IP64

Maximum weight without cable

3.5 kg

Operating temperature

0...+70°C

Storage temperature

-30...+85°C

Maximum humidity (non-condensing)

98%

Permissible vibration (55 to 2000 Hz)

≤ 100 m/s²

Permissible shock (11 ms)

≤ 300m/s²

Electronical Data 
 

Version

A170-A ∫ 11 µApp

A170-AV ∫ 1 Vpp

A170-F Π TTL

Supply voltage

+ 5 V ± 5 %; 100 mA max

+ 5 V ± 5 %; 120 mA max

+ 5 V ± 5 %; 150 mA max

Light source

LED

LED

LED

Incremental signals

Two sinusoidal I1 and I2 
Amplitude at 1 kΩ load:
- I1 = 7 - 16 µA
- I2 = 7 - 16 µA

Differential sine +A / -A and +B / -B
Amplitude at 120 kΩ load:
- A = 0.6 - 1.2 V
- B = 0.6 - 1.2 V

Differential square-wave U1 / U1and U2 / U2. Signal levels at 20 mA load current:
- low (logic "0") ≤ 0.5 V 
- high (logic "1") ≥ 2.4 V

 

Reference signal

One quasi-triangular I0 peek per revolution. Signal magnitude at 1 kW load:
- I0 = 2 - 8 µA (usable component)

One quasi-triangular +R and its complementary -R per revolution. Signals magnitude at 120 W load:
- R = 2- 8 V (usable component)

One differential square-wave U0 / U0 per revolution. Signal levels at 20 mA load current:
- low (logic "0") < 0.5 V 
- high (logic "1") > 2.4 V

Maximum operating frequency

(-3 dB) ≥ 160 kHz

(-3 dB) ≥ 180 kHz

160-2500 kHz (depends on the interpolation factor)

Direction of signals

I2 lags I1 for clockwise rotation (viewed from shaft side)

+ B lags + A in clockwise rotation (viewed from shaft side)

U2 lags with U1 in clockwise rotation (viewed from shaft side)

Maximum rise and fall time

-

-

< 0.5 μs

Standard cable length

1 m; without connector

1 m; without connector

1 m; without connector

Maximum cable length

5 m

25 m

25 m