Click to reach us online

SST20 Inclinometer

Vigor Technology MEMS Inclinometer / SST20 Inclinometer

Features 

  • Low cost, high performance, suitable for batch application 
  • 50Hz refresh rate, 10Hz response frequency 
  • ±0.07°accuracy@-15~50℃ 
  • ±0.2% cross-axis error 
  • Available to horizontal, vertical, headstand, etc installation methods 
  • IP67protection 
  • 9~36VDC power supply 
  • Sensing elements survive to 1500g shock while operating 


Applications 
Vessel, Engineering machinery, Solar/wind energy, automobile/truck/vehicle, Communication/electric Tower monitoring, High-voltage pylon monitoring, Antenna, construction engineering, Landslide, etc

 SST20 Inclinometer
Output Interface RS232/RS485/CAN/CANOpen/Switch 0.5~4.5VDC/4~20mA
Measurement
range
±5°、±10°、±15°、±30°、±45°、±60°、±90°、  ±180°、0~360°
Accuracy ±0.07°@-15~50℃  ±0.15°@-15~50℃
Non-linearity ±0.03° ±0.05°
Resolution 0.002 ° 0.005°
Repeatability ±0.02°  ±0.05°
Offset ±0.02° ±0.05°
Cross-axis
sensitivity
±0.2%FS  ±0.2%FS
Measuring axis 1 or 2 axis(±180°and 0~360°measurement range single axis only)
Bandwidth Default 3Hz,5Hz、10Hz available
Response time 5ms(no filtering) 10ms(no filtering)
Refresh rate Default 5Hz,max. 50Hz 50Hz
Cold start
warming time
Less than 60s
Interface
features
RS232: 9600bps (adjustable), 8 data bits, 1 start bit, 1 stop bit Voltage output: 0.5~4.5VDC;
Internal resistance 0.3Ω;
Drive current (max.) 15mA
RS485: 9600bps (adjustable), 8 data bits, 1 start bit, 1 stop bit
No matched resistance
CAN2.0: according to ISO11898-2 standard, 40k~1MBit/s baud rate,
adaptive standard frame and extended frame format
No matched resistance
CANOpen: according to DS301 standard, 40k~1MBit/s baud rate
No matched resistance
Current output: 4~20mA;
Internal resistance 50MΩ;
load impedance 150~650Ω
Switch output: Darlington OC output, load with1A @9~36VDC, alarm
point can be pre-set in factory
Power
consumption
RS232/RS485 Output: 9~36VDC, current ≤50mA@24VDC 16~36VDC
current≤30mA(no-load)@24VDC
CAN/CANOpen Output: 9~36VDC, current≤80mA@24VDC
Switch output: 9~36VDC,current≤50mA(no-load)@24VDC
Operation
temperature
range
-40~85℃
Storage
temperature
range
-40~85℃
EMC According to EN 61000/GBT17626
Insolation ≥100MΩ
MTBF 10 years
Shock 100g@11ms, three-axis, half- sine
Vibration 8grms,20~2000Hz
Protection IP67
Connector M12 5-Pin socket
Weight ≤200g (no connector or cable)

Demisions (mm)

Wiring

Explanations: land supply alarm alarm tilt meter, provides factory input only for alarm point. STAY
The use of alarm point with special request must specify all requests when ordering. The uniaxial tiltometer has only the X axis.